Power Cuts in Malta: What Happens to Your Equipment, and How a UPS Helps

Close-up of power cables with red connectors in an equipment rack

An uninterruptible power supply (UPS) is a battery unit that keeps equipment running when the mains fails. For servers, storage and production machines, its job is to give them a few minutes to shut down properly. Most of the damage from a power cut comes from equipment that stopped mid-write or mid-cycle.

Malta lost power again on 8 October 2026. Large parts of Malta and Gozo went dark in the morning. Enemalta described the cause as human error during work on a circuit breaker at the Magħtab terminal station, which triggered the grid’s automatic protection. Supply came back progressively over the following hours (Malta Independent, MaltaToday).

What happens to equipment when the power drops?

When the power drops, servers, NAS units, coders and label printers stop where they are, with files open and writes half finished. Some of it comes back without complaint. Servers, storage and inkjet coders often do not. A few minutes of battery and a shutdown signal are enough to avoid most of it.

What happens to a server in a power cut?

A server that loses power mid-write can leave a database or a virtual machine’s disk in an inconsistent state. Often it comes back after a recovery check; sometimes it needs a restore. The restart then takes longer than the cut did, because services come up in order and someone has to confirm that what came back is complete.

A UPS prevents this only if it carries the server long enough and tells it to shut down before the battery runs out. The second part needs a connection: a USB cable to a single server, or a network card such as Eaton’s Network-M3 with shutdown software on each server, so that one UPS can shut several machines down in the right order.

Does a NAS need a UPS?

Yes, because a NAS that loses power drops with its volumes still mounted and its writes in flight. Connected to a UPS, a Synology NAS enters Standby Mode when the power fails: it stops all services and unmounts its volumes to prevent data loss and shut down safely before the UPS runs out of power (Synology Knowledge Center).

The NAS has to be told about the UPS. The connection can be USB, SNMP over the network, or another Synology unit acting as a network UPS server. If the signal travels over the network, the switch in between must be on the UPS too. Otherwise, Synology notes, the UPS information cannot be relayed during the outage. Synology also recommends testing by pulling the UPS’s power cable before relying on it. We test it with you by pulling the plug, out of hours and after a backup has been checked. Setting this up is part of every Synology install we do.

What does a power cut do to an inkjet coder?

A power cut skips the coder’s shutdown flush. When a Domino Ax-Series continuous inkjet printer is shut down properly, the print head runs an auto-flush cycle “to prevent ink from drying” and “blocking inside the ink jet nozzle and print head gutter” (Domino knowledge base). Domino also warns that wake-up mode, which keeps the ink moving during long idle periods, is disabled if power is disconnected from the printer.

A customer’s Ax-Series coder was powered down without its shutdown flush, it clogged, and we sent a technician on site. Keeping the coder powered long enough for an operator to run the normal shutdown avoids the main cause of it. If the coder is not on a UPS, put the shutdown on the outage checklist, and ask us before adding one so the UPS is matched to the coder’s actual draw. Our CIJ explainer and the Domino range have more on how these printers work.

What happens to a label printer in a power cut?

A label printer that loses power mid-job loses the job. Someone then has to match the labels that did print against the order, resend the rest and throw away the half-printed ones. Desktop thermal label printers draw little, so a small UPS gives them the seconds they need to finish or cancel cleanly. We supply and service Zebra label printers and barcode scanners.

Which equipment should stay on through a power cut?

Door controllers, card readers, the camera recorder, the core switch, the firewall and the internet router are the equipment to keep running through the whole cut. They all draw little power compared with a server, so a UPS with extended battery modules (EBMs) added can keep them going for hours. A door-access system usually draws under 400 W. For one we quoted an Eaton 9SX 2000 with two EBMs, which Eaton’s runtime calculator puts at about seven hours at that load. Doors keep working on cards and the cameras keep recording while the rest of the building is dark.

The network also carries the shutdown signals. Switches, Wi-Fi access points, VoIP phones and card terminals reboot one by one when the power returns. If the switch is not on a UPS, servers that rely on a network signal from the UPS cannot receive it.

Some Eaton units let you decide which outlets get the battery. The Eaton 5PX Gen2 takes up to four EBMs and splits its outlets into load segments. That lets you switch non-essential equipment off early and keep the remaining battery for the doors and the network. The online 9SX Gen2 takes up to four EBMs as well and has two controlled outlet groups.

Before you put door hardware on a UPS, ask your access control installer how the locks behave without power. Depending on the lock type, a door either releases when it loses power, so that people can get out in a fire, or stays locked. The installer should confirm that the UPS does not change how the doors respond to the fire alarm.

What each kind of equipment risks in a power cut, and the setup that avoids it:

EquipmentWhat an uncontrolled stop risksWhat to set up
Servers, virtual hostsInconsistent databases and disks, long restart, possible restoreUPS sized for shutdown or ride-through; network card and shutdown software; tested shutdown order
NAS and storageVolumes not unmounted cleanly, writes lost, consistency checksUPS support enabled on the NAS (USB or SNMP); switch on the UPS if signalled over the network; Standby Mode timing set
Inkjet codersShutdown flush skipped, risk of ink drying in the nozzle and gutterPower kept long enough for the normal shutdown, or a shutdown step in the outage checklist
Label printersJobs lost mid-print, wasted labels, manual reconciliationA small UPS to finish or cancel the job cleanly; check what printed
Access control, cameras, network, phonesDoors off cards, no recording, no phones or internet; shutdown signals never reach the serversUPS with EBMs for hours of runtime; non-essential outlets switched off early; lock behaviour confirmed with the installer

Do brownouts and voltage dips matter as much as a power cut?

A brownout is a sustained drop in voltage below normal. To a server or a NAS, a dip is an uncontrolled stop or a reboot, the same as a cut. Power that is restored progressively, as it was on 8 October, can bring further dips and short interruptions. Each one is another uncontrolled stop for anything unprotected.

A line-interactive UPS corrects everyday sags and swells with its voltage regulator and switches to battery almost instantly when the power fails. An online double-conversion UPS feeds the load from its own inverter all the time, so the equipment never sees the raw mains. Our guide to line-interactive vs online UPS explains which suits which load.

Is a UPS on its own enough?

No. A UPS without a shutdown signal only delays the crash. It carries the load until the battery is empty, and then everything drops exactly as it would have without it, a few minutes later. What protects the equipment is enough runtime, a connection to each server and NAS, and a shutdown order that someone has tested. We cover all three as part of UPS supply, installation and service in Malta.

Eaton UPS units give you that connection over USB to a single machine, or over the network through a management card such as the Network-M3 (we have also written up whether a UPS network card is a security risk). Eaton’s power management software then shuts machines down in the order you set.

Once UPS support is enabled in DSM, a Synology NAS reads an Eaton UPS’s status over USB or SNMP and enters Standby Mode without extra software on the NAS. The UPS settings on the NAS, and on a Network-M3 card if the signal travels over the network, still have to be configured.

How long should a UPS run for?

Minutes: long enough for a clean shutdown of the servers and storage, which is what we usually size for. Hours are realistic only for low-draw equipment such as the network and door access, with battery modules added. Our UPS sizing guide has the figures and works out the runtime from the load in watts.

When do you need a generator instead?

When servers or production have to keep running through a cut that lasts hours. Batteries can carry a network cabinet that long, but carrying a server room or a production line for hours on batteries alone gets expensive quickly. A clean shutdown for the servers and hours of battery for the network and doors cover most sites; add a generator only where something has to keep working.

Is your UPS battery still up to it?

Not if it is more than three years old and nobody has tested it. A UPS battery typically lasts three to five years, less in a hot cupboard (see our guide to when to replace a UPS battery for the signs). A UPS that has not been tested since it was installed may carry nothing when the next cut comes. We replace worn batteries with Yuasa sealed lead-acid batteries (12 V blocks, or 6 V blocks for some models) and recycle the old ones through the ERA scheme.

Before the next cut, check:
  • every server, NAS and switch is on a UPS and receives a shutdown signal;
  • when the shutdown was last tested by pulling the plug;
  • how old the UPS batteries are;
  • whether the network and door access can run for as long as you need;
  • that coders and printers not on a UPS have a shutdown step on the outage checklist.

How Sirap sets this up

We size Eaton UPS units to your real load and to the job each one has to do. That might be a line-interactive Eaton 5P for a small network cabinet, a 5PX with battery modules for doors and networking, or an online 9SX for servers and storage. We fit the Network-M3 card, set up the shutdown of your servers and Synology NAS units, and test it with you by pulling the plug. SirapCare agreements extend the warranty to five years and add preventive maintenance and priority response. We have been an Eaton partner in Malta since 1988, and we have written up why an Eaton UPS costs what it does.

Tell us what is in the cupboard and we will tell you what it needs, including when the UPS you already have is fine and only the battery or the shutdown setup is missing. A quote needs the list of equipment, the load in watts if you know it, and the runtime you want. UPS price is on request.

Eaton 5PX Gen2 line-interactive UPS, one UPS with LCD beside four extended battery modules

Featured Products in this article

HOW WE DO
Picture of Kurt Paris

Kurt Paris

Kurt Paris, Director, Sirap. 20+ years in IT solutions and software engineering. MSc in Software Engineering, Zebra-certified.

Related articles

Contact us

Talk to us about your next project

Tell us what you need to run, code, label, store, protect or automate. Our technical sales team in San Gwann replies within one working day, in Maltese or English.

Who you deal with:
What happens next?
1

We reply within one working day

2

An engineer visits if the site needs a look

3

You get a quote with part codes, installation and warranty

Schedule a Free Consultation